COSEL MH3 Series 3W High Isolation DC/DC Converter Press Release

COSEL released a new 3W high isolation DC/DC converter for medical and industrial applications. The COSEL MH3 series uses a single in-line (SIP) 8 package with reinforced insulation of 3kVAC, 4.2kVDC, meets the medical isolation standard (2MOOP (250VAC)), and is reinforced for use in industrial applications where input/output voltage differences may occur. Three input voltages (4.5V-18V; 9V-36V and 18V-76V) are available, with single output (MHFS3) and dual output (MHFW3) options to suit a wide range of applications. The MH3 is designed for performance, with a maximum isolation capacitance of only 20pF to reduce noise transmission. COSEL's unique MH3 is manufactured in Japan and comes with a 5-year warranty.


COSEL MH3 Series 3W High Isolation DC/DC Converter Press Release - cover page
Brand
Cosel
Category
DC/DC Converters
Document type
Other
Language
Chinese
Pages
4
File format
PDF
File size
884 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
80726F33AF3DEF423CDDABC063073907

About this manual

This is a COSEL press release dated 2020-08-31 (reference PR-20:004_CN_MHF3) announcing the MH3 series of 3W high isolation DC/DC converters for medical and industrial applications. The series is offered in a single in-line (SIP) 8 package with single output types (MHFS3) and dual output types (MHFW3), and is manufactured in Japan with a 5-year warranty.

The release describes 3kVAC and 4.2kVDC reinforced isolation, medical 2MOPP (250VAC) isolation, a maximum input/output capacitance of 20pF, and three 4:1 wide input ranges (4.5V-18V, 9V-36V, 18V-76V). It also covers overcurrent protection with automatic recovery, a negative-logic remote control pin, operation from -40 to +85°C at 20% to 95% RH (non-condensing), vibration and shock testing, safety certifications (UL62368-1, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1 3rd edition) and the 22.0 x 12.0 x 9.5 mm, 7 g SIP8 package. This manual is written in Chinese.

What's inside

  • Product features
  • Product announcement
  • Reinforced insulation for industrial applications
  • Medical isolation (2MOPP, 250VAC)
  • Wide 4:1 input voltage ranges
  • Single and dual output voltage options
  • Overcurrent protection and remote control
  • Vibration and shock testing
  • Safety certifications
  • Package, dimensions and company information

Specifications

Output power3W
Input/output isolation voltage3kVAC, 4.2kVDC
Medical isolation2MOPP, 250VAC working isolation voltage
Maximum input/output capacitance20pF
Input voltage ranges (4:1)4.5V-18V; 9V-36V; 18V-76V
Single output voltages (MHFS3)3.3V, 5V, 9V, 12V, 15V
Dual output voltages (MHFW3)+/-12V and +/-15V
Operating ambient temperature-40 to +85°C
Relative humidity20% to 95% (non-condensing)
Package and dimensionsSIP8, 22.0 x 12.0 x 9.5 mm
Maximum weight7 g
Warranty5 years

Frequently asked questions

What input voltage ranges does the COSEL MH3 series offer?

Three wide 4:1 input ranges are offered: 4.5V to 18V, 9V to 36V and 18V to 76V.

What output voltages are available in the MH3 series?

Single output MHFS3 types come in 3.3V, 5V, 9V, 12V and 15V; dual output MHFW3 types come in +/-12V and +/-15V.

What is the isolation capacitance of the MH3 series?

The maximum isolation capacitance is 20pF, which the release says reduces noise transmission.

Which safety standards is the MH3 series certified to?

It is certified to UL62368-1, EN62368-1, c-UL, ANSI/AAMI ES60601-1 and EN60601-1 third edition.