This document is the PLA-Series Cosel product manual, which introduces the product's functional characteristics and usage methods
This manual provides detailed instructions for installing and operating Cosel PLA-Series AC-DC power supplies. It covers input voltage ranges, inrush current protection, overcurrent and overvoltage protection, thermal protection, and output voltage adjustment. The document also explains series and parallel operation options and includes technical specifications for various models like PLA15F, PLA30F, PLA50F, PLA100F, PLA150F, PLA300F, and PLA600F.
Support is available worldwide through FORTEC Elektronik AG offices in Germany, Austria, Switzerland, Great Britain, and the USA, with contact details provided for technical inquiries.
| Input Voltage Range | AC85-264V |
|---|---|
| Maximum Output Power | PLA15F: 7.5W, PLA30F: 10W, PLA50F: 15W, PLA100F: 40W, PLA150F: 60W |
| Overcurrent Protection | Built-in, activates at >105% of rated output current |
| Overvoltage Protection | Built-in, requires 3-minute cooldown after shutdown |
| No Load Power Consumption | PLA15F: 1.0W typ, PLA100F/150F: 1.5W typ |
The rated input voltage range is AC85-264V. For safety, use AC100-240V (50/60Hz).
Overcurrent protection activates at >105% of rated output current. The power supply recovers automatically when the condition is removed.
Yes, the output voltage can be adjusted within the specified range by turning the built-in potentiometer clockwise (up) or counterclockwise (down).