Centurion Systems M-FRB Multi-Function Relay Wiring Guide

Wiring guide for the Centurion Systems M-FRB Multi-Function Relay Board, covering relay, LED driver, traffic light and inductive sensor configurations.


Centurion Systems M-FRB Multi-Function Relay Wiring Guide - cover page
Brand
CENTURION SYSTEMS
Category
RELAY
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
222 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
18B802CC12281E2190FEB8343D89200F

About this manual

The M-FRB is an interface board that lets a low-current and/or low-voltage output drive a high-voltage and/or high-current load, rated at 3 A at 230 VAC or 28 VDC non-inductive. It can be configured by jumper as a relay switched by a positive or negative output, an LED extender, or an interface card for a PNP or NPN inductive sensor.

The guide gives electrical specifications and wiring for using the board as a relay, to control a Midi Traffic Light, as a Multi-LED Driver, and as an inductive sensor interface for Direct Drive or Independent Drive Claws. A diagnostic LED shows when the relay is energised.

What's inside

  • Introduction
  • Electrical Specifications
  • Wiring
  • Wiring the M-FRB as a relay
  • Wiring the M-FRB to control a Midi Traffic Light
  • Wiring the M-FRB as a Multi-LED Driver
  • Wiring the M-FRB as an Inductive Sensor Interface for use with Direct Drive or Independent Drive Claws

Specifications

Input Voltage Maximum13.6 V
Input Voltage Minimum10.6 V
Current Consumption40 mA +/- 10%
Relay Output3 A at 230 VAC or 28 VDC, non-inductive

Frequently asked questions

What can the M-FRB be configured to do?

It can act as a relay switched by a positive or negative output, an LED extender for multiple LEDs or other indicating devices, or an interface card for a PNP or NPN inductive sensor.

Which jumper is used for an inductive sensor with a PNP output?

Place the jumper on J2.

Which jumper is used for an inductive sensor with an NPN output?

Place the jumper on J3.

What does the diagnostic LED indicate?

It is ON when the relay is energised and OFF when it is de-energised.

Download PDF (222 KB)

More CENTURION SYSTEMS Manuals


View all CENTURION SYSTEMS manuals →