Wiring guide for the Centurion Systems M-FRB Multi-Function Relay Board, covering relay, LED driver, traffic light and inductive sensor configurations.
The M-FRB is an interface board that lets a low-current and/or low-voltage output drive a high-voltage and/or high-current load, rated at 3 A at 230 VAC or 28 VDC non-inductive. It can be configured by jumper as a relay switched by a positive or negative output, an LED extender, or an interface card for a PNP or NPN inductive sensor.
The guide gives electrical specifications and wiring for using the board as a relay, to control a Midi Traffic Light, as a Multi-LED Driver, and as an inductive sensor interface for Direct Drive or Independent Drive Claws. A diagnostic LED shows when the relay is energised.
| Input Voltage Maximum | 13.6 V |
|---|---|
| Input Voltage Minimum | 10.6 V |
| Current Consumption | 40 mA +/- 10% |
| Relay Output | 3 A at 230 VAC or 28 VDC, non-inductive |
It can act as a relay switched by a positive or negative output, an LED extender for multiple LEDs or other indicating devices, or an interface card for a PNP or NPN inductive sensor.
Place the jumper on J2.
Place the jumper on J3.
It is ON when the relay is energised and OFF when it is de-energised.