This manual describes the installation of the SECTOR II traffic barrier.
This manual provides comprehensive instructions for the installation of the SECTOR II traffic barrier manufactured by Centurion Systems. It covers the entire process from unpacking and physical mounting to electrical wiring and commissioning. The document includes specific procedures for installing loop detectors and safety beams, as well as setting up the internal controller.
| Input voltage | 90 - 240V AC ±10%, 50 Hz |
|---|---|
| Motor voltage | 12V DC |
| Battery capacity | 7 Ah |
| Boom pole length options | 3.0M, 4.5M, 6.0M |
| Maximum operations per day | 3000 |
| Operating temperature range | -20°C to 55°C |
| Receiver frequency | 433.92 MHz |
All installation, repair, and service work must be carried out by a suitably qualified person.
A 5A thermal breaker with all-pole circuit break is recommended.
An earth leakage circuit breaker with a threshold of 30mA must be fitted upstream of the system.
The manual override is operated using a 6mm Allen key from outside of the unit.