Bently Nevada 330400 and 330425 Accelerometer Acceleration Transducers Datasheet

Technical specifications, environmental limits, and ordering information for Bently Nevada 330400 and 330425 accelerometers designed for critical machinery…


Bently Nevada 330400 and 330425 Accelerometer Acceleration Transducers Datasheet - cover page
Brand
Bently Nevada
Category
Industrial Robot
Document type
Datasheet
Language
English
Pages
9
File format
PDF
File size
948 KB
Published
27 October, 2026
Updated
27 October, 2026
MD5 checksum
FE44524725698D45F8E3C857D8411740

About this manual

This datasheet details the specifications for the Bently Nevada 330400 and 330425 Accelerometer Acceleration Transducers, intended for critical machinery applications such as gear mesh monitoring. The 330400 model provides an amplitude range of 50 g peak with a sensitivity of 100 mV/g, while the 330425 offers a larger amplitude range of 75 g peak with a sensitivity of 25 mV/g. Both units are designed to meet American Petroleum Institute Standard 670 requirements.

What's inside

  • Description
  • Specifications
  • Environmental Limits
  • Compliance and Certifications
  • Hazardous Area Approvals
  • Ordering Information
  • Accessories
  • Graphs and Figures

Specifications

Sensitivity (330400)100 mV/g
Sensitivity (330425)25 mV/g
Acceleration Range (330400)50 g peak
Acceleration Range (330425)75 g peak
Frequency Response10 Hz to 15 kHz
Operating Temperature-55°C to +121°C
Shock Survivability5000 g peak
Case Material316L stainless steel
Maximum Cable Length305 metres (1000 ft)

Frequently asked questions

What is the difference between the 330400 and 330425 accelerometers?

The 330425 provides a larger amplitude range of 75 g peak and a sensitivity of 25 mV/g, whereas the 330400 has a range of 50 g peak and a sensitivity of 100 mV/g.

What is the frequency response of these transducers?

Both units have a frequency response of 10 Hz to 15 kHz, with ±3dB tolerance.

Are these accelerometers suitable for hazardous areas?

Yes, they have hazardous area approvals including Intrinsically Safe Ex ia IIC T4 and Ex nL IIC T4 for various classes and groups.

Download PDF (948 KB)