Bendix D-2 governor service manual covering operation, preventive maintenance, service tests, adjustment, leakage testing, removal, installation, and…
The Bendix D-2 governor automatically controls air pressure in air brake or air supply systems between maximum cut-out and minimum cut-in pressures. It works with the compressor unloading mechanism and provides mounting holes for direct or remote installation.
This document includes description, operation, preventive maintenance, service and operating tests, safety guidelines, leakage tests, and procedures for removing, installing, and disassembling the governor.
| Reservoir ports | 3 (1/8 inch P.T.) |
|---|---|
| Unloader ports | 3 (1/8 inch P.T.) |
| Exhaust port | 1 (1/8 inch P.T.) |
| Mounting | Direct to compressor or remote |
| Common cut-out pressure | 105-125 psi |
| Common cut-in pressure | 90-105 psi |
| Inspection interval | 6 months or 1500 operating hours |
| Adjustment per 1/4 turn | Approximately 4 psi |
At a minimum, it should be inspected every 6 months or 1500 operating hours, whichever comes first, for proper operation.
No, the exhaust port should never be blocked or plugged to allow the governor to function properly.
Each 1/4 turn raises or lowers the pressure setting approximately 4 psi.
Common cut-in pressures are between 90 and 105 psi.