This service bulletin outlines inspection procedures for housing distortion, installation of coil retention and cover sealing kits, and return procedures…
This document serves as a technical service bulletin for Bendix D-2000 and D-2200 Series Magnetos. It addresses potential housing distortion caused by the tightening of center cover screws and provides instructions for correcting this issue using specific kits, such as the Bendix P/N 10-382939 Coil Retention Kit and P/N 10-682007 Cover Sealing Kit. The bulletin details how to identify equipment compliance categories and the necessary steps to achieve full compliance.
Compliance is required at the first opportunity, but in any case no later than 100 operating hours after receipt of this Service Bulletin.
A Category 1 system is identified by the presence of four "POP" rivets in place of the four center screws in the magneto/harness cover and the letter "D" stamped on the bottom line of the nameplate.
A magneto must be returned to the factory if it exceeds the specified limits of housing distortion, specifically if more than 0.008 inch feeler gage stock can be inserted between the block corners and the gage plate.