Becker O 5.10 Vacuum Pump Operating Instructions

Becker O 5.10 vacuum pump operating instructions covering oil types and fill quantities, electrical connection, maintenance intervals and technical data.


Becker O 5.10 Vacuum Pump Operating Instructions - cover page
Brand
Becker
Category
Other
Document type
User Manual
Language
German
Pages
8
File format
PDF
File size
4.6 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
22225335FC82890DF1CACC4E68DF59A4

About this manual

These are the operating instructions for the Becker O 5.10 vacuum pump, issued by Gebr. Becker GmbH in Wuppertal, Germany. The document covers two versions: Type 1 with a short oil tank and Type 2 with a long oil tank. It includes mounting and ambient conditions, oil types and quantities, the electrical connection and the maintenance schedule.

The pages are largely diagram-based and use short labels with multilingual headings. They show permitted ambient temperature and installation altitude, the type plate layout, the oil fill limits for each tank type, the single-phase electrical connection with cable lengths up to 2 m and from 2 m to 10 m, and the maintenance points for intake air, ambient air and oil changes. This manual is written in German.

What's inside

  • Type 1 with short oil tank / Type 2 with long oil tank
  • Oil
  • Ambient temperature
  • Electrical connection
  • Maintenance
  • Intake air
  • Ambient air
  • Oil change intervals

Specifications

Weight, Type 117 kg (37.5 lbs)
Weight, Type 218.5 kg (41 lbs)
Oil quantity, Type 1max. 0.3 liter
Oil quantity, Type 2max. 0.5 liter
Sound pressure level at 50 Hz58.5 dB(A)
Sound pressure level at 60 Hz64 dB(A)
Ambient temperature rangeabove 5 °C / 41 °F and below 40 °C / 104 °F
Maximum starting frequency12 times per hour
Oil change intervals1st = 500 h, 2nd = 2000 h, 3rd = 4000 h

Frequently asked questions

What oil types are listed for the O 5.10?

The oil table lists Becker Lube in the grades M, S, SL and SM in viscosity 32 and 68, chosen according to ambient temperature. The document gives article numbers for the 1 l, 5 l, 0.5 l and 0.25 l containers.

How much oil goes into each tank type?

Type 1 with the short oil tank takes a maximum of 0.3 liter and Type 2 with the long oil tank a maximum of 0.5 liter.

What are the oil change intervals?

The maintenance page lists the first oil change at 500 h, the second at 2000 h and the third at 4000 h.

How is the single-phase electrical connection made?

The document shows a 1-phase standard connection with a cable length of up to 2 m, and a different arrangement for more than 2 m up to 10 m. A capacitor with Faston 6.3 terminals is shown in the connection diagram.

Download PDF (4.6 MB)

More Becker Manuals


View all Becker manuals →