This is the second edition of the SAR-DF 517 4-Band Precision Direction Finder Installation and Operation Manual by Becker Flugfunkwerk GmbH, released in January 2002.
This manual covers the Becker SAR-DF 517 4-band precision direction finder, including general information, technical data, installation, wiring, and post-installation checks.
It also describes operation, bearing modes, adjustable training frequencies, and error messages for the display and antenna units.
| Main voltage supply low threshold | <10.0 V |
|---|---|
| Antenna unit voltage supply low threshold | <9.0 V |
The main voltage input is too low, below 10.0 V.
Channels 1...28 and 60...88 of sea-station.
There is no serial data (RS485) from the antenna unit, or the connection or antenna unit is damaged.
The voltage supply at the antenna unit is too low, below 9.0 V, or there is a considerable voltage drop.