This document is the operating manual of Vads 1500 45kW compressor
This operating manual covers the Becker VADS 1500 45 kW VARIAIR direct screw unit, which is used to produce negative pressure (vacuum) or to generate pressure. It describes safety instructions, transportation, assembly, installation, oil filling, connection, initial operation, maintenance, and control of the unit.
The manual also explains the frequency inverter display, security devices for process air and oil circulation, operating modes, parameter overview, construction diagrams, technical specification, and maintenance of the filter cartridge.
| Ambient temperature | 5 to 40 °C |
|---|---|
| Rear clearance | At least 50 cm |
| Side clearance | At least 80 cm |
| Front clearance | At least 80 cm |
| Oil type | BECKER LUBE G70 or ISO VG 68 |
| Oil change interval | After 5000 operating hours and at least once per year |
| Oil level limit | Must not drop below 2/3 of the view window |
| Oil temperature release value | 60 °C |
| Vacuum revolutions | 110 (min.) |
| Pressure revolutions | 80 (min.) |
| Vacuum setting range | 200 to 1000 mbar abs |
| Pressure setting range | 1000 to 2000 mbar abs |
| Switching limit | Avoid more than 10 switches per hour |
Use the oil brand BECKER LUBE G70, or alternatively oil complying with ISO VG 68.
Change the oil and oil filters after 5000 operating hours and at least once per year.
The permissible ambient temperature is 5 °C to 40 °C.
If the oil temperature exceeds the 60 °C release value, the unit will be shut down.