Becker roller shutter motor installation manual
This installation manual from Becker-Antriebe GmbH describes the commissioning of Becker tubular drives for roller shutters and sun protection systems, and of specific Becker control units. It is written for technicians trained by Becker-Antriebe and refers readers to the safety instructions at the end of the manual and to the Assembly and Operating Instructions supplied with each product.
The manual first explains the roller shutter drive types and how an installed drive type can be identified, then covers the individual drive families and control units, followed by drives for sun shading devices and the Centronic and B-Tronic radio technology. Individual sections deal with setting limit positions, wiring and radio receiver handling.
| Operating mode | Short-period operation S2 |
|---|---|
| Continuous operation before cool-off | 4 minutes |
| Changeover time for switching the running direction | At least 0.5 seconds |
| Tube diameter by drive size | P - 35 mm, R - 45 mm, L - 58 mm |
| Maximum barrel rotation in one direction | 38 revolutions |
| Drive adapter fixing hole | 4 mm |
Connect the drive wires to a programming unit and press the programming button for 2 seconds; the number of clicks and the drive's reaction indicate the type.
The changeover time for switching the running direction must be at least 0.5 seconds.
After 4 minutes of continuous operation the drive must be allowed to cool off.
The barrel may not be turned more than 38 revolutions in one direction.