Becker Roller Shutter and Sun Protection Drives Installation Manual

Becker roller shutter motor installation manual


Becker Roller Shutter and Sun Protection Drives Installation Manual - cover page
Brand
Becker
Category
Motor
Document type
Installation Guide
Language
English
Pages
162
File format
PDF
File size
19.2 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
E798E016592F65CFA2FCFA7FD09F6990

About this manual

This installation manual from Becker-Antriebe GmbH describes the commissioning of Becker tubular drives for roller shutters and sun protection systems, and of specific Becker control units. It is written for technicians trained by Becker-Antriebe and refers readers to the safety instructions at the end of the manual and to the Assembly and Operating Instructions supplied with each product.

The manual first explains the roller shutter drive types and how an installed drive type can be identified, then covers the individual drive families and control units, followed by drives for sun shading devices and the Centronic and B-Tronic radio technology. Individual sections deal with setting limit positions, wiring and radio receiver handling.

What's inside

  • Roller shutter drive types
  • Identification of the drive type
  • M (M04) drives
  • M17 drives
  • PicoR+ drives
  • R(+) drives
  • RO+ (E02) drives
  • Control units
  • Drives for sun shading devices
  • Centronic radio technology

Specifications

Operating modeShort-period operation S2
Continuous operation before cool-off4 minutes
Changeover time for switching the running directionAt least 0.5 seconds
Tube diameter by drive sizeP - 35 mm, R - 45 mm, L - 58 mm
Maximum barrel rotation in one direction38 revolutions
Drive adapter fixing hole4 mm

Frequently asked questions

How can I tell which roller shutter drive type is installed?

Connect the drive wires to a programming unit and press the programming button for 2 seconds; the number of clicks and the drive's reaction indicate the type.

What is the minimum changeover time when switching the running direction?

The changeover time for switching the running direction must be at least 0.5 seconds.

How long may the drive run continuously?

After 4 minutes of continuous operation the drive must be allowed to cool off.

How far may the barrel be turned in one direction?

The barrel may not be turned more than 38 revolutions in one direction.