This document is a user manual for maintenance of U5-Series vacuum pump
This manual provides step-by-step instructions for maintaining the Becker U5-Series vacuum pump. It covers daily oil checks, oil changes every 500–1000 hours, and replacement of separation elements and filters every 2000 hours. It also includes troubleshooting for common issues like smoking oil, wrong oil usage, clogged float chambers, and worn separation elements.
The guide includes visual diagrams for procedures such as draining oil, installing new filters, and replacing gas ballast filters. It specifies that only Becker Vacuum Pump oil (part number 3SVPO-100) should be used and recommends using genuine Becker parts for replacements.
| Oil Change Interval | Every 500-1000 Hours |
|---|---|
| Separation Element Replacement | Every 2000 Hours or at least 2 times per year |
| Recommended Oil | Becker Vacuum Pump oil 3SVPO-100 |
Only Becker Vacuum Pump oil 3SVPO-100 should be used.
The oil filter should be replaced every 2000 hours or at least twice per year.
Run the pump against the gas ballast for 1–2 hours to remove water contamination.