This instruction manual covers the installation, wiring, specifications, and operating conditions of the Banner Engineering R45C IO-Link Device to Analog…
The R45C is a compact, rugged converter designed to output an analog value (voltage or current) based on numerical data sent from an IO-Link Master via Process Data Out (PDO). It features a robust overmolded design meeting IP65, IP67, and IP68 ratings, allowing for direct connection to sensors or in-line installation. The device includes status indicators for power, IO-Link communication, and analog output status.
| Supply Voltage | 18 V DC to 30 V DC |
|---|---|
| Power Pass-Through Current | 4 A maximum |
| Leakage Current Immunity | 400 µA |
| Resolution | 14 bits |
| Accuracy | 0.5% |
| Environmental Rating | IP65, IP67, IP68 |
| Operating Temperature | -40 °C to +70 °C |
The allowable current range is 0 mA to 24 mA, and the allowable voltage range is 0 V to 11 V.
The actual analog output value will be set to one of three selectable levels (Low, High, or Hold) after a 2-second delay.
The mounting hole accepts M4 (#8) hardware, and the minimum screw length required is 12.9 mm plus the counterbore depth plus 3 mm.