Balluff BCS R08RRE-PSM80C-EP00,3-GS75 capacitive sensor (order code BCS012T): electrical, mechanical and environmental specifications, wiring and connector…
This datasheet covers the Balluff capacitive sensor BCS R08RRE-PSM80C-EP00,3-GS75, order code BCS012T, from the R08 series in a block-style PP housing measuring 34 x 16 x 8 mm. It lists basic features, display and operation indicators, electrical connection data, electrical data, environmental conditions, interface, materials, mechanical data, range/distance values and remarks on calibration and teaching.
The sensor operates on 12...30 VDC with a PNP normally open (NO) switching output rated at 50 mA, has a measuring range of 1...8 mm and a real switching distance of 8 mm, and is rated IP67 for use from -25...70 °C. The document also includes connector and wiring diagrams and help views.
| Operating voltage Ub | 12...30 VDC |
|---|---|
| Rated operating voltage Ue | 24 V DC |
| Rated operating current Ie | 50 mA |
| Switching output | PNP normally open (NO) |
| Measuring range | 1...8 mm |
| Real switching distance sr | 8 mm |
| Switching frequency | 50 Hz |
| Hysteresis H max. | 15.0 % of Sr |
| Repeat accuracy max. | 5.0 % of Sr |
| Voltage drop static max. | 1.5 V |
| Ambient temperature | -25...70 °C |
| IP rating | IP67 |
| MTTF (40 °C) | 98 a |
| Dimension | 34 x 16 x 8 mm |
| Housing material | PP |
| Sensing surface material | PP |
| Tightening torque | 0.2 Nm |
| Connection | 4-pin, cable length 0.3 m, cable diameter 3.40 mm |
| Installation | For flush mounting |
| Ready delay tv max. | 200 ms |
It has a PNP normally open (NO) switching output.
The measuring range is 1...8 mm, with a real switching distance of 8 mm.
Input DI can be used for teaching the switching point; in normal operation input DI should be connected continuously to L-.
The sensor is rated for -25...70 °C ambient temperature and has an IP67 rating.