This datasheet details the specifications, typical uses, and ordering codes for Ashcroft B-Series pressure, differential pressure, and hydraulic switches.
This document provides technical specifications and typical applications for the Ashcroft B-Series of pressure, differential pressure, and hydraulic switches. The switches are designed for use in demanding industrial environments such as offshore oil rigs, chemical plants, and power generation facilities. Key features include adjustable setpoints, explosion-proof enclosures, and SIL 3 capability for safety-critical applications.
| Setpoint | Factory set or field adjustable |
|---|---|
| Setpoint Accuracy | ±1% of full range |
| Repeatability | ±1% of range per 50 °F |
| Enclosure Rating (B4/Hydraulic) | NEMA 4X, IP66 |
| Enclosure Rating (B7) | NEMA 7/9, IP66 |
| Ambient Temperature Range | -20°F to 150°F |
| Process Temperature Range (Buna N or Teflon) | 0 °F to 150 °F |
| Process Temperature Range (Viton) | 20 °F to 300 °F |
| Pressure Ranges | Vacuum to 7500 psi |
| SIL Capability | SIL 3 Capable |
They are used in offshore oil rigs, chemical and petrochemical plants, pulp and paper mills, steel mills, and power plants.
The pressure ranges extend from vacuum up to 7500 psi.
Yes, the B7 enclosure provides explosion-proof protection meeting NEMA 7/9 and IP66 requirements.
Yes, the B and D series are capable of SIL 3 certification.