Ashcroft quick guide covering process pressure gauges 1279, 1377, 1379 and 2462 with specifications and features.
This Ashcroft quick guide lists product features and specifications for process pressure gauges, along with a table of contents for pressure gauges, switches, transducers, seals, temperature indicators, test instruments and accessories.
The process pressure gauge section gives dial sizes, accuracy, dampening, connections, wetted materials, temperature limits, ranges, units, weather protection and approvals for models 1279, 1377, 1379 and 2462.
| 1279 dial size | 4½ in |
|---|---|
| Accuracy | ±0.5% of span (ASME B40.100 Grade 2A) |
| Dampening | Glycerin, silicone, Halocarbon, PLUS! Performance |
| Process connection | ¼ NPT, ½ NPT male |
| Process connection location | Lower, back |
| Mounting options | 1279: stem, surface, flush; 1377: stem, flush; 1379: stem, surface, flush; 2462: stem, surface, flush |
| Wetted Bourdon tube | Bronze, 316L SS, Monel (1379 also Inconel) |
| Process connection materials | Brass, 316L SS, Monel, steel |
| Case | 1279 phenolic; 1377 and 1379 aluminum; 2462 polypropylene |
| Window | Glass, acrylic, safety glass, non-glare glass |
| Ring | 1279 and 1379 polycarbonate (UL 94 V-0); 1377 steel, black enamel; 2462 polypropylene |
| Pressure relief back | 1279 and 1379 polycarbonate (UL 94 V-0); 1377 stainless steel; 2462 polypropylene |
| Dry process temperature limit | -20 to 250 F (-29 to 121 C) |
| PLUS! temperature limit | -40 to 200 F (-40 to 93 C) |
| Glycerin fill temperature limit | 20 to 150 F (-7 to 66 C) |
| Silicone or Halocarbon fill temperature limit | -40 to 200 F (-40 to 93 C) |
| Pressure range | Vacuum, compound, 15 to 30,000 psi (1379 to 100,000 psi) |
| Units | psi, bar, kg/cm2, kPa |
| Dry case weather protection | Case not sealed; weather-protected environment only |
| Liquid-filled weather protection | IP66 or NEMA 4X |
| Approvals | CRN |
The listed accuracy is ±0.5% of span (ASME B40.100 Grade 2A).
The listed process connections are ¼ NPT and ½ NPT male.
Dry case is not sealed, liquid-filled is IP66 or NEMA 4X, and hermetically sealed is IP66.
CRN is listed as an approval.