aD D2008 Electronic Weighing Scale User Manual

This manual provides operating instructions for the aD D2008 electronic weighing scale, covering technical parameters, daily operations, data storage, and…


aD D2008 Electronic Weighing Scale User Manual - cover page
Brand
AD
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
236 KB
Published
17 October, 2026
Updated
17 October, 2026
MD5 checksum
B18C67C6A5EC57CD6FFD359A7B68B659

About this manual

The document serves as a user guide for the aD D2008 series of electronic weighing instruments. It details the technical specifications, including RS485 interfaces and various communication protocols supported by the device.

The manual provides step-by-step instructions for routine operations such as power-on zeroing, tare adjustment, date/time settings, and vehicle number management. It also explains how to store weighing records and print detailed reports or cumulative totals. This manual is written in Chinese.

What's inside

  • Technical Parameters
  • Power On & Zeroing
  • Tare Operations
  • Date and Time Settings
  • Data Storage Methods
  • Vehicle Number & Tare Setup
  • Record Printing
  • Information Prompts

Specifications

Communication Protocol SupportC, E, F, and K type digital protocols
Display Type7-digit LED display with 7 status indicators
Data Storage Capacity1500 latest weighing records and 1000 vehicle number tare weights
Operating Temperature0°C to 40°C

Frequently asked questions

What is the fixed password for checking vehicle number tare weights?

The fixed password is "111111".

How many weighing records can the instrument store automatically?

It can store up to 1500 latest weighing records, deleting the oldest when full.

Download PDF (236 KB)