Bühler GAS 222.xx ATEX 2 Series Gas Sampling Probe Installation Manual

This document is the installation and user manual for the Gas Sampling Probe 222.xx ATEX 2 series. The document provides information on safety precautions, product description, transportation and storage requirements, installation and wiring connections, operation and maintenance. The Gas Sampling Probe is a product of Bühler Technologies GmbH and is used as an important component in gas analysis systems for gas pre-processing.


Brand
Buhler
Document type
Installation Guide
Language
Chinese
Pages
28
File format
PDF
File size
2.4 MB
Updated
28 September, 2023
MD5 checksum
5BFEE757CB42B13ED0BD5C8FDCE549BD

About this manual

This manual provides step‑by‑step instructions for installing and operating the GAS 222.xx ATEX 2 series gas sampling probe. It emphasizes safety requirements, such as using only original parts, installing the device in explosion‑proof circuits, and having qualified personnel perform the work.

The guide details mechanical installation, pipe and electrical connections, back‑flush system setup, and routine maintenance. It also includes troubleshooting, disposal procedures, and reference tables for chemical resistance and part numbers. This manual is written in Chinese.

What's inside

  • Overview
  • Safety Precautions
  • Nameplate Information
  • Product Description
  • Transportation and Storage Requirements
  • Installation and Wiring
  • Operation and Maintenance
  • Troubleshooting
  • Repair and Disposal
  • Additional Documents

Specifications

Maximum Working Pressure10 bar
Maximum Working Temperature50 °C
Power Supply Voltage / Frequency115 V / 230 V AC, 50 Hz / 60 Hz
Heating Elements2 PTC cartridges
Alarm Output LimitsUmax = 30 V, Imax = 100 mA

Frequently asked questions

What safety measures are required before installing the GAS 222.xx ATEX 2 probe?

The device must be installed by qualified personnel, in an explosion‑proof circuit, using only original parts, and all safety instructions in the manual must be followed.

How should the probe be stored when not in use?

Store the probe in a dry, dust‑free, temperature‑controlled space between –20 °C and +60 °C, preferably in its original packaging or suitable repackaging.

What is the required power supply for the probe?

The probe operates on 115 V / 230 V AC at 50 Hz / 60 Hz as indicated on the nameplate.

What is the maximum pressure for the back‑flush gas tank?

The back‑flush gas tank is rated for a maximum working pressure of 10 bar.