This is the user manual of Delta Aquarius UPS series, introducing the features and characteristics of the product and how to use it.
This manual covers unpacking, required accessories, and step‑by‑step installation of the Water Bottle UPS, including connecting the PC, LCD monitor, RJ11 phone line, and USB communication cable. It also explains how to configure the Delta Power Management Master 2000 monitoring software and how to power on and off the unit.
Later sections describe routine maintenance, battery replacement procedures, indicator‑lamp meanings, fault diagnosis, and the technical specifications such as rated capacity, input voltage range, discharge time, and dimensions. This manual is written in Chinese.
| Rated Capacity | 375VA |
|---|---|
| Input Voltage Range | 92Vac~132Vac |
| Input Frequency | 60 Hz |
| Discharge Time (PC + LCD) | ≥ 8 minutes |
| Charging Time to 90 % Capacity | ≤ 16 hours |
| Communication Interface | USB 1.1 (1 port) |
| Operating Temperature | 0 °C ~ 35 °C |
| Relative Humidity | 10 % ~ 90 % |
| Noise Level | < 42 dB (1 m) |
| Dimensions (W×D×H) | 119 mm × 364 mm × 90 mm |
| Weight | 4.3 kg |
Charge the UPS for at least 8 hours before the first use to allow the battery to reach optimal condition.
A flashing yellow light with a beep every 10 seconds means the UPS is running on battery power.
Remove the battery cover, pull out the old battery, connect the new battery (small spark is normal), and re‑install the cover, avoiding metal jewelry or tools that could short the terminals.
Press and hold the power button for at least 3 seconds until you hear a beep and the green panel light turns on.