This manual provides users with installation, parameter setting, fault diagnosis, elimination and daily maintenance of AC motor drives.
This manual explains how to install and operate the Delta VFD-M series AC motor drive. It includes safety warnings, proper grounding, wiring diagrams, panel operation, parameter configuration and troubleshooting steps.
Detailed sections cover mechanical dimensions, wiring, simple panel operation, parameter tables, fault diagnosis, protection actions, regular maintenance and a comprehensive appendix with accessory selection and motor‑selection guidelines. This manual is written in Chinese.
| Input Voltage | 3‑phase 200‑240 V |
|---|---|
| Input Current | 6.0 A |
| Output Voltage | 3‑phase 0‑240 V |
| Output Current | 5.0 A |
| Output Power | 1.9 kVA |
| Frequency Range | 0.1 – 400 Hz |
| Maximum Applicable Motor | 0.5 HP (0.4 kW) |
The drive must be correctly and reliably grounded before use.
Check the drive for any transport damage and verify that the model matches the box information.
Store the unit at an ambient temperature between –20 °C and +60 °C.