This guide describes the mechanical and electrical installation of the ACSM1-04 drive module (0.75 to 45 kW)
This guide describes the mechanical and electrical installation of the ABB ACSM1-04 drive module for 0.75 to 45 kW. It includes safety precautions, installation design requirements, mechanical mounting, power and control cable connections, wiring diagrams, and terminal settings.
The drive module has an IP20 protection rating for controlled indoor environments. Installation requires disconnecting power and waiting at least 5 minutes before work, and the guide specifies cable shielding, grounding, and tightening torque requirements for different model ranges. This manual is written in Chinese.
| Protection rating | IP20 (UL open type) |
|---|---|
| Maximum ambient temperature at rated current | 40 °C (104 °F) |
| Current derating temperature range | 41 to 55 °C (104 to 131 °F) |
| Circuit capacity | Peak current up to 100,000 rms, maximum 480 V |
| Motor-circuit cable derating temperature | 75 °C (167 °F) |
| Input cable protection | Fuse or circuit breaker |
| X1 external input power | 24 V DC, 1.6 A |
| X2 relay output | 250 V AC / 30 V DC, 2 A |
| Maximum total current | 200 mA |
At least 5 minutes must be allowed for the intermediate circuit capacitors to discharge.
It is IP20 (UL open type).
40 °C (104 °F).
3 N·m (25 lbf·in), or 15 N·m (11 lbf·ft).