This manual is intended for engineers and technicians who install, commission, operate, and troubleshoot the RSYC-01 synch unit in drive systems. It assumes knowledge of electrical principles, wiring, and drive hardware.
The document covers safety notices, mechanical and electrical installation, wiring diagrams, terminal descriptions, parameter configuration, technical data, fault handling, and physical dimensions. Appendices provide additional reference manuals and parameter tables for related ABB drives. This manual is written in Chinese.
| Power supply voltage | 24 V DC (-5 … +5%) |
|---|---|
| Power consumption | 25 … 35 mA |
| Synchronization accuracy | -21 … +21° |
| Signal cable type | JAMAK by NK Cables 2 × (2+1) × 0.5 mm² |
| Installation rail size | 7.5 × 35 mm (EN50022) |
It requires a 24 V DC power supply with a tolerance of –5 % to +5 %.
All safety notices supplied with the drive must be read in full before installation, commissioning, or use.