The Omron E3X-DA-S/MDA Series Digital Fiber Sensor Instruction Sheet describes precautions required for installing and operating the Amplifier Unit and Fiber Unit. It identifies the package contents, part names, display and key functions, and the SET/RUN operating modes.
The document explains basic settings such as light-ON/dark-ON selection, power adjustment, manual and automatic teaching, reflective-sensor teaching, and maximum-sensitivity threshold setting. It also lists ratings and specifications, display information, key operations, and precautions for correct and safe use.
| Supply voltage | 12 to 24 VDC ±10%, ripple (p-p) 10% max. |
|---|---|
| Power consumption | 960 mW max. (40 mA max. at 24 V) |
| Control output type | Open collector |
| Load current | 50 mA max. |
| Residual voltage | 1 V max. |
| Off-state current | 10μA max. |
| Timer function | OFF, OFF-delay, ON-delay, or one-shot |
| Timer time | 1 ms to 5 s |
| Mutual interference prevention | Supported (optical communications sync method) |
| Default power tuning target value | 2,000 |
| Maximum extension wire length | 100 m max. |
It requires 12 to 24 VDC ±10% with ripple (p-p) 10% max.
Press the key for approximately 1 second, then release it.
Adjust the Head to decrease the incident light level or execute power tuning, then repeat the operation.
Use the E3X-MC11-SV2 Mobile Console; other consoles such as the E3X-MC11 cannot be used.