About this manual

The SITRANS LU 01 is an ultrasonic level monitoring system from Siemens that measures liquid or solid levels without contacting the material. It uses a Siemens‑Milltronics ultrasonic probe and optional temperature sensor to calculate distance based on echo time.

The instruction manual covers product specifications, installation requirements, electrical characteristics, probe mounting, wiring diagrams, programming via the handheld controller, Dolphin Plus software or SmartLinx, supported communication protocols, and detailed fault‑diagnosis procedures such as the LOE error display. This manual is written in Chinese.

What's inside

  • Introduction
  • Installation
  • Electrical Characteristics
  • Probe Installation
  • Programming
  • Communication
  • Specifications
  • Troubleshooting

Specifications

AC power supply100/115/200/230 V AC ±15%, 50/60 Hz, 31 VA
DC power supply18 V to 30 V DC, 25 W
Measurement range0.3 m (1 ft) to 60 m (200 ft)
Accuracy0.25 % of range or 6 mm (whichever is larger)
Resolution0.1 % of range or 2 mm (whichever is larger)
Temperature compensation range-50 °C to 150 °C
4‑20 mA output loadMaximum load 750 Ω

Frequently asked questions

What is the measurement range of the SITRANS LU 01?

It can measure from 0.3 m (1 ft) up to 60 m (200 ft).

Which communication protocols are supported?

The device supports PROFIBUS DP, Allen‑Bradley Remote I/O, Modbus RTU and DeviceNet.

What does a flashing “LOE” display indicate?

A flashing “LOE” indicates a measurement fault; the manual lists checks such as probe alignment and target surface within range.