The Dell EMC XC640 Hyper-Converged Appliance Getting Started Guide provides setup and usage instructions for the appliance.
This two-page getting started guide for the Dell EMC XC640 hyper-converged appliance explains the initial setup steps: before you begin, connect the appliance to power, connect the network cable and optional I/O devices, loop and secure the power cable with the retention strap, and turn on the appliance. It also refers readers to rack documentation for installing and securing the appliance in a rack.
The guide includes safety and documentation notes, including the requirement to use EPP-compliant power supply units and to install the operating system before adding hardware or software not purchased with the appliance. The technical specifications section lists power supply ratings, the 3 V CR2032 system battery, and a maximum continuous operating ambient temperature of 40°C/104°F.
| 2000 W Platinum AC power supply | 2000 W, 100–240 V, 50/60 Hz, 11.5 A |
|---|---|
| 1600 W Platinum AC power supply | 1600 W, 200–240 V, 50/60 Hz, 10 A |
| 1100 W Platinum AC power supply | 1100 W, 100–240 V, 50/60 Hz, 12 A–6.5 A |
| 750 W Platinum AC power supply | 750 W, 100–240 V, 50/60 Hz, 10 A–5 A |
| 1100 W DC power supply | 1100 W, -(48–60) V, 32 A |
| System battery | 3 V CR2032 lithium coin cell |
| Maximum ambient temperature for continuous operation | 40°C/104°F |
Follow the safety instructions in the Safety, Environmental, and Regulatory Information document shipped with the appliance.
Use Extended Power Performance (EPP) compliant power supply units, indicated by the EPP label.
The maximum ambient temperature for continuous operation is 40°C/104°F.