Siemens SITRANS LG240 Foundation Fieldbus Level Sensor Operating Instructions

The SITRANS LG240 is a radar level transmitter with the following features: - Non-contact measurement - High accuracy - High reliability - Easy to install and maintain


Siemens SITRANS LG240 Foundation Fieldbus Level Sensor Operating Instructions - cover page
Brand
Siemens
Category
radar
Document type
User Manual
Language
Chinese
Pages
80
File format
PDF
File size
4.3 MB
Published
25 November, 2023
Updated
25 November, 2023
MD5 checksum
4DCCDE2CF1A10B590247DCA801FBD7A8

About this manual

The Siemens SITRANS LG240 is a level sensor with a polished rod measuring probe. It is used for continuous level and interface measurement, especially in the food and pharmaceutical industries. High-frequency microwave pulses travel along a cable or rod, are reflected at the medium surface, and the instrument analyzes the travel time as the level.

The operating instructions cover safety information, product description, installation, connection to the power supply, commissioning with the display and adjustment module or PACTware, diagnostics and service, dismounting, and technical data. The document applies to hardware from version 1.0.0 and software from version 1.3.0, for instrument versions without a SIL certificate. This manual is written in Chinese.

What's inside

  • About this documentation
  • Safety
  • Product description
  • Installation
  • Connecting to the power supply
  • Commissioning with the display and adjustment module
  • Commissioning with PACTware
  • Diagnostics and service
  • Dismounting
  • Technical data

Specifications

Measurement principleHigh-frequency microwave pulses travel along a cable or rod
Minimum dielectric constant of upper medium1.6
Minimum upper medium thickness50 mm (1.97 in)
Lower medium dielectric requirementAt least 10 times the dielectric constant of the upper medium
Hardware versionFrom 1.0.0
Software versionFrom 1.3.0
Standard electronics typeFX80FF

Frequently asked questions

What does the SITRANS LG240 measure?

It continuously measures level and interface, particularly in food and pharmaceutical applications.

What is the minimum dielectric constant of the upper medium for interface measurement?

The minimum dielectric constant is 1.6.

Which electronics type is described in this document?

The document describes the FX80FF standard electronics.

Which software version does this document apply to?

It applies from software version 1.3.0.

Download PDF (4.3 MB)

More Siemens Manuals