The SITRANS LG240 is a radar level transmitter with the following features: - Non-contact measurement - High accuracy - High reliability - Easy to install and maintain
The Siemens SITRANS LG240 is a level sensor with a polished rod measuring probe. It is used for continuous level and interface measurement, especially in the food and pharmaceutical industries. High-frequency microwave pulses travel along a cable or rod, are reflected at the medium surface, and the instrument analyzes the travel time as the level.
The operating instructions cover safety information, product description, installation, connection to the power supply, commissioning with the display and adjustment module or PACTware, diagnostics and service, dismounting, and technical data. The document applies to hardware from version 1.0.0 and software from version 1.3.0, for instrument versions without a SIL certificate. This manual is written in Chinese.
| Measurement principle | High-frequency microwave pulses travel along a cable or rod |
|---|---|
| Minimum dielectric constant of upper medium | 1.6 |
| Minimum upper medium thickness | 50 mm (1.97 in) |
| Lower medium dielectric requirement | At least 10 times the dielectric constant of the upper medium |
| Hardware version | From 1.0.0 |
| Software version | From 1.3.0 |
| Standard electronics type | FX80FF |
It continuously measures level and interface, particularly in food and pharmaceutical applications.
The minimum dielectric constant is 1.6.
The document describes the FX80FF standard electronics.
It applies from software version 1.3.0.