The Dell FluidFS NAS Solutions Getting Started Guide introduces the features and benefits of the E02T and C11M Series products.
This Spanish-language guide covers unpacking and installing a Dell FluidFS NAS Solutions system in a rack, connecting and securing power cables, powering on the system, and installing the optional bezel.
It also provides technical and environmental specifications, Dell software license information, support resources, and regulatory NOM details. This manual is written in Spanish.
| AC power supply power (per power supply) | 717 W |
|---|---|
| Heat dissipation | 2446.8 BTU/hr |
| AC input voltage | 90 V AC to 264 V AC, automatic range, 47 Hz/63 Hz |
| Controller storage backup power supply | 12.8 V to 13.2 V, 4.8 Ah to 6 Ah, 63 Wh to 77 Wh |
| Height | 86.40 mm (3.40 inches) |
| Width with rack locks | 481.50 mm (18.96 inches) |
| Width without rack locks | 446.30 mm (17.57 inches) |
| Depth without bezel and handle | 741.00 mm (29.21 inches) |
| Depth with bezel and handle | 813.10 mm (32.01 inches) |
| Maximum weight | 30.50 kg (67.0 lb) |
| Empty weight | 12.86 kg (28.36 lb) |
| Operating temperature | 5 C to 40 C (41 F to 104 F) |
| Storage temperature | -40 C to 60 C (-40 F to 140 F) |
| Operating relative humidity | 20% to 80% (non-condensing) |
| Storage relative humidity | 5% to 95% |
| Operating vibration | 0.26 Grms |
| Storage vibration | 1.88 Grms |
| Operating shock | 31 G |
| Storage shock | 27 G |
| Operating altitude | -16 m to 3,048 m (-50 ft to 10,000 ft) |
| Storage altitude | -15.2 m to 10,668 m (-50 ft to 35,000 ft) |
| Air contamination class | Class G1 per ISA-S71.04-1985 |
| NOM supply voltage | 100-240 V AC |
| NOM frequency | 50/60 Hz |
| NOM power consumption | 10 - 6.5 A X2 |
It turns on automatically when power is connected to a power source.
It is available online at support.dell.com/manuals.
Call the customer support phone number.
Yes, connect each to an independent power source for maximum redundancy.