The document provides operating instructions for the WIKA model 2 pressure gauge with explosion protection.
This document provides operating instructions for WIKA Model 2 pressure gauges, specifically designed for use in hazardous areas according to ATEX standards. It covers general information, safety requirements, and intended use for industrial applications involving liquid or gaseous media.
| Pressure limitation (Steady) | Full scale value |
|---|---|
| Pressure limitation (Fluctuating) | 0.9 x full scale value |
| Pressure limitation (Short time) | 1.3 x full scale value |
| Temperature effect | max. ±0.4 %/10 K of full scale value |
| Case ingress protection (Model 2xx, PG23CP, PG28) | IP65, IP66 |
These pressure gauges are used for measuring pressure in hazardous areas of industrial applications.
They are suitable for liquid or gaseous media, group 1 (dangerous), provided they are not harmful to the wetted parts.
The responsibility for classification of zones lies with the plant operator and not the manufacturer/supplier.