Dell PowerEdge T320 Getting Started Guide Regulatory Model: E20S Series Regulatory Type: E20S001
Unpack the Dell PowerEdge T320, extend the tower feet if used, and connect the keyboard, mouse, monitor, and power cables. The guide also covers securing power cables, turning on the system, installing the optional bezel, and completing operating system setup.
Technical specifications include power supply wattage, heat dissipation, physical dimensions, weight, and environmental limits. The guide also notes safety, regulatory, warranty, and support information.
| AC power supply wattage | 350 W, 495 W, or 750 W |
|---|---|
| Heat dissipation (495 W power supply) | 1908 BTU/hr maximum |
| Heat dissipation (750 W power supply) | 2891 BTU/hr maximum |
| Heat dissipation (350 W non-redundant power supply) | 1456 BTU/hr maximum |
| AC input voltage | 100 V AC to 240 V AC, autoranging, 50 Hz/60 Hz |
| Coin-cell battery | 3 V CR2032 lithium coin cell |
| Tower height with feet | 443.3 mm (17.45 inch) |
| Tower height without feet | 430.3 mm (16.94 inch) |
| Tower width with feet opened | 304.5 mm (11.99 inch) |
| Tower width with feet closed | 218 mm (8.58 inch) |
| Tower depth without bezel | 542.2 mm (21.35 inch) |
| Tower depth with bezel | 558.6 mm (21.99 inch) |
| Rack height | 218 mm (8.58 inch) |
| Rack width without ears | 430.3 mm (16.94 inch) |
| Rack width with ears | 482.4 mm (18.99 inch) |
| Rack depth minimum | 538.4 mm (21.2 inch) |
| Rack depth maximum | 584.05 mm (22.99 inch) |
| Maximum configuration weight | 29.55 kg (65.14 lb) |
| Empty weight | 15.6 kg (34.39 lb) |
| Operating temperature | 10 °C to 35 °C |
| Storage temperature | –40 °C to 65 °C (–40 °F to 149 °F) |
| Operating relative humidity | 10% to 80% RH, with 26 °C maximum dew point |
| Storage relative humidity | 5% to 95% RH ambient with 33 °C (91 °F) maximum dew point |
| Operating vibration | 0.26 Grms at 5 Hz to 350 Hz |
| Storage vibration | 1.87 Grms at 10 Hz to 500 Hz for 15 min |
| Operating shock | One shock pulse in the positive z axis of 31 G for 2.6 ms |
| Storage shock | Six consecutively executed shock pulses in positive and negative x, y, and z axes |
| Operating altitude | –15.2 m to 3048 m (–50 to 10,000 ft) |
| Storage altitude | –15.2 m to 10,668 m (–50 ft to 35,000 ft) |
| Airborne contaminant level | Class G1 as defined by ISA-S71.04-1985 |
The AC power supply is available in 350 W, 495 W, or 750 W.
The Owner's Manual is available online at support.dell.com/manuals.
It uses a 3 V CR2032 lithium coin cell.
Be sure the operating system is installed before installing hardware or software not purchased with the system.