This document provides Dell EMC Networking OS9 switch configuration examples and topology options for a VxRail 4.5 cluster deployment.
This guide provides Dell EMC Networking OS9 switch configuration examples and topology options for deploying a VxRail 4.5 cluster, including dual-switch VLT, dual-switch without VLT, and single-switch options.
It covers hardware such as S5048F-ON leaf switches, an S3048-ON out-of-band management switch, and VxRail 14G nodes, along with validation commands and validated components.
| S5048F-ON form factor | 1-Rack Unit (RU), multilayer switch |
|---|---|
| S5048F-ON ports | 48x25GbE, 6x100GbE, or 72x25GbE |
| S3048-ON ports | 48x1GbE BASE-T and 4x10GbE SFP+ |
| VxRail P Series CPU and memory | Up to 44 CPU cores and 1536GB memory |
| VxRail P Series storage | 24TB hybrid or 46TB all-flash storage |
| VxRail node rNDC option | 2x25GbE SFP28 ports |
| VxRail Appliance software version | 4.5.200 |
The guide uses two S5048F-ON switches as leaf switches.
The guide uses one S3048-ON switch for out-of-band management traffic.
Using VLT is the preferred topology.
The deployment examples use a VxRail cluster consisting of four P570 nodes.