Dell PowerVault NAS Systems Running Windows Storage Server 2012 Troubleshooting Guide

Dell PowerVault Network Attached Storage (NAS) Systems Running Windows Storage Server 2012 Troubleshooting Guide


Dell PowerVault NAS Systems Running Windows Storage Server 2012 Troubleshooting Guide - cover page
Brand
DELL
Category
Storage devices
Document type
User Manual
Language
Spanish
Pages
16
File format
PDF
File size
250 KB
Published
19 November, 2023
Updated
19 November, 2023
MD5 checksum
F0405A8267C73C1F6DBB7D5BFE266AB2

About this manual

This guide provides troubleshooting procedures for Dell PowerVault Network Attached Storage (NAS) systems that run Windows Storage Server 2012. It addresses common errors encountered during installation, deployment, administration, and updates, with step-by-step solutions for each issue.

The document is organized into five chapters: installation issues (including RAID configuration mismatches and error codes -5000 through -5007), deployment issues (missing default password and PERC card errors), administration issues (incorrect system information, insufficient iSCSI volume space, security server deactivation), update issues (OpenManage Server Administrator not detected), and getting help (contacting Dell, related documentation, service tag location, and documentation feedback). This manual is written in Spanish.

What's inside

  • Notas, precauciones y avisos
  • Capítulo 1: Problemas de instalación
  • Después de reemplazar las unidades de disco duro o reinstalar el sistema operativo, la configuración RAID no coincide con la configuración de fábrica y con los valores predeterminados de RAID 1
  • Error: -5000 muestra un mensaje de error de sistema inesperado
  • Error: -5001 muestra un mensaje de error de sistema no válido
  • Error: -5002 muestra un mensaje de error de configuración de hardware incompatible
  • Error: -5003 se produce al crear un volumen del sistema operativo
  • Error: -5004 se produce al crear un volumen del sistema operativo
  • Error: -5005 se produce al crear un volumen del sistema operativo
  • Error: -5006 se produce al crear un volumen del sistema operativo

Frequently asked questions

What does error -5000 indicate on a Dell PowerVault NAS system?

Error -5000 means a required system resource is missing or defective, often due to an invalid state of the OS reinstallation media, optical drive, or system.

How to resolve error -5002 (incompatible hardware configuration) on a Dell PowerVault NAS?

Ensure the disk controller card is properly connected to internal drives and seated in the correct slot, verify the internal drive controller works in the PERC BIOS, and confirm the system supports an internal drive controller.

Why does the LCD screen show the last reinstallation error message until the OS is successfully reinstalled?

The last error message remains on the LCD until the operating system has been successfully reinstalled; changing the user-defined string to default or a new string in the Embedded Server Management BIOS screen clears it.

Download PDF (250 KB)