The document is a service manual for the Fleck 5600SXT Down Flow Water Softener.
Spanish-language service manual for the Fleck 5600SXT down-flow water softener. It covers installation requirements, startup, discharge and conditioning, control features, timer operation, user and master programming, diagnostic mode, meter and clock components, valve assemblies, accessories, troubleshooting, flow diagrams, wiring, service instructions, and injector flow data.
The manual also includes a task specification sheet, programming tables, safety brine valve assemblies, bypass valve assemblies, and injector flow and extraction speed information. This manual is written in Spanish.
| Minimum water pressure | 20 psi (1.4 bar) |
|---|---|
| Maximum water pressure | 125 psi (8.6 bar) |
| Maximum water temperature | 110°F (43°C) |
| Electrical supply | Uninterrupted 120 VAC |
| Control voltage | 12 VDC from transformer |
| Residential drain line size | At least 1/2 in (13 mm) |
| Drain line air gap | 2 times drain line diameter, minimum 1 in |
A minimum water pressure of 20 psi (1.4 bar) is required for the regeneration valve to work effectively.
It requires an uninterrupted 120 VAC supply, and the control uses a transformer to supply 12 VDC.
Water pressure must not exceed 125 psi (8.6 bar) and water temperature must not exceed 110°F (43°C).
Residential drain line piping must be at least 1/2 inch (13 mm).