The Fugle 1-1 use flow type automatic softener is a kind of softener that realizes full automatic control of each step of the operation and regeneration of the softener by adopting time flow or sensor to start regeneration. The device can provide water continuously (or intermittently).
This manual provides detailed instructions for installing, configuring, and maintaining the FLECK 9000/9500 series water‑softener controller. It covers the overall workflow, component layout, and the steps required to set up the system for automatic regeneration.
The guide also includes cleaning cycles, troubleshooting tips, and specifications such as required water pressure, operating temperature, and power supply. Safety precautions and pipe‑material recommendations are provided to ensure reliable operation in food‑processing, laundry, and other industrial applications. This manual is written in Japanese.
| Water pressure range | 0.2 MPa – 0.6 MPa |
|---|---|
| Operating temperature | 2 °C – 50 °C |
| Outlet water hardness | 0.03 mmol/L |
| Power supply | 220 V / 50 Hz AC |
| Resin type | 001X7 strong‑acid cation‑exchange resin |
The controller operates with a water pressure between 0.2 MPa and 0.6 MPa.
It requires a 220 V, 50 Hz AC power supply.
The system uses 001X7 strong‑acid cation‑exchange resin.