Service manual for the FLECK 5600 water softener covering installation, start-up, system disinfection, and troubleshooting procedures.
This document serves as a service manual for the FLECK 5600 water softener, providing detailed instructions for installation, start-up, and maintenance. It includes specific procedures for different configurations, such as those with time clocks or backwash filters, and outlines necessary safety precautions and environmental limits.
| Minimum operating pressure | 20 psi / 1.4 bar / 138 kPa |
|---|---|
| Maximum operating pressure | 125 psi / 8.61 bar / 861 kPa |
| Minimum water temperature | 34° F / 1° C |
| Maximum water temperature | 110° F / 43° C |
| Maximum Ambient temperature | 120° F / 52° C |
| Maximum humidity | 75% |
| Input Voltage | 120 Volts AC / 60 Hz |
| Maximum Watts | 3 watts |
| Maximum altitude | 2000 meters |
The maximum pressure rating is 125 psi (8.6 bar).
Only silicone lubricant should be used.
Do not use granulated or rock salt.