Service manual for the FLECK 5810 and 5812 XTR2 water softener control valve, covering installation, operation, programming, troubleshooting, and technical…
This document serves as a service manual for the FLECK 5810 and 5812 XTR2 water softener or filter control valves. It provides detailed instructions for installation, including plumbing requirements, electrical connections, and safety precautions. The manual also covers the operation of the XTR2 touchscreen control, explaining features such as regeneration cycles, settings, diagnostics, and navigation.
| Minimum Pressure | 20 psi/1.4 bar/138 kPa |
|---|---|
| Maximum Pressure | 125 psi/8.61 bar/861 kPa |
| Input Voltage | 100-240 VAC |
| Output Voltage | 12 VDC |
| Output Current | 2.0 amps |
| Maximum Altitude | 2,000 meters |
The maximum water temperature is 110°F (43°C).
Only silicone lubricant should be used for the distributor and tank O-ring seals.
The pipe size for a residential drain line should be a minimum of 1/2" (13 mm).