Asundar ASD906-36V10A300W Simulated Battery User Manual

ASD906-36V10A300W Simulated Battery has charging and discharging functions, can simulate 36V 10A battery, maximum charging 30V 10A, maximum discharging 36V 10A, ASD906-36V10A300W Simulated Battery can simulate battery charging and discharging phenomena, thus replacing the battery for ordinary adapter or mobile power supply PCBA board function or performance testing. Mainly used in mobile power supply, adapter


Asundar ASD906-36V10A300W Simulated Battery User Manual - cover page
Brand
Asundar
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
21
File format
PDF
File size
1 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
7CEA1CC027842F30356E88393041E946

About this manual

The ASD906-36V10A300W simulated battery provides charge and discharge functions and can simulate a 36 V 10 A battery, with maximum charge of 30 V 10 A and maximum discharge of 36 V 10 A. It can replace a battery for functional or performance testing of PCBA boards in products such as power banks, adapters, Bluetooth earphones, and Bluetooth speakers, and can also be used as an adjustable power supply.

It has a 4.3-inch high-definition LCD touch screen, supports PC control through upper-computer software, can set continuously changing dynamic voltage within a specified time, and displays voltage and current versus time curves. Features include charge/discharge switching, six voltage setting memories, standby current detection, and microamp-level display in the mA range. This manual is written in Chinese.

What's inside

  • Inspection and Installation
  • Quick Start
  • Technical Specifications
  • Functional Features
  • Basic Operation
  • Device Interfaces
  • FAQ
  • Warranty Agreement

Specifications

Input/output voltage0~36 V
Current0~10 A
Power0~300 W
Voltage setting resolution1 mV
Voltage setting accuracy0.05%+2 mV
Voltage readback resolution1 mV
Current readback resolution1 μA (<10 mA), 1 mA (≥10 mA)
Voltage readback accuracy0.05%+2 mV
Current readback accuracy0.15%+5 μA (<10 mA); 0.15%+4 mA (10 mA≤I<10 A)
Load regulation (voltage)<0.1%
Line regulation (voltage)<0.1%
Ripple (voltage)100 mVp-p
AC input voltage100~240 VAC
AC input frequency50~60 Hz
Cooling60 mm × 60 mm × 25 mm fan
Operating temperature0 to 40 °C
Device dimensions300 mm × 220.5 mm × 97 mm
Package dimensions360 mm × 295 mm × 175 mm
Device weight2.5 kg
Package weight3.1 kg
Operating humidityMaximum 80%, no condensation
Installation dimensions250 mm D × 220.5 mm W × 97 mm H
Bottom height16.5 mm
Height with stand47 mm

Frequently asked questions

What should I check if the device screen is black after power-on?

Check that the switch is set correctly, the power supply is normal, and the fuse is not blown; if it remains black, return it for repair.

Why can't the voltage be set to the preset value?

The simulated battery voltage does not exceed 36 V, and changes smaller than 0.01 V can be made with the fine-tuning knob.

Why can't the current protection value be set as preset?

The peak current protection value is 10 A and the maximum protection time is 255 mS.

When does the device enter protection state?

It enters protection when actual input/output parameters exceed the limits or when internal temperature becomes too high after long high-power operation.