ASD863+651 AC/DC testing device consists of ASD863 multi-protocol load meter, ASD651 PF digital power meter, Android operation terminal and the main function is to test the functions, parameters and performance of external power adapter PCBA and finished products. The load meter integrates 4 independent programmable multi-protocol electronic load modules. On the basis of the basic functions of ordinary electronic load meters, it also supports QC, PD fast charging protocols, and can be expanded independently to 6 load modules. It supports multiple power interfaces, and is equipped with automatic testing function, which can quickly complete the functional testing and parameter testing of power adapter.
The Asundar ASD863+651 AC/DC testing device consists of an ASD863 multi-protocol load tester, an ASD651 PF digital power meter, and an Android operation terminal. It is mainly used for functional detection, parameter testing, and performance evaluation of external power supplies such as power adapters, PCBA, and finished products.
The load tester integrates four independent programmable multi-protocol electronic load modules and supports manual research mode and automatic testing. It supports QC, PD, PPS, AFC, FCP, SCP, SSCP, VOOC, and SVOOC protocols, and can export test results to USB storage devices. This manual is written in Chinese.
| Channels | 4 (CH1, CH2, CH3, CH4) |
|---|---|
| Voltage measurement range | 0-24 V |
| Rated current | 0-10 A |
| Rated power | 100 W; 150 W in production automatic test |
| Supported protocols | QC2.0/PD2.0/QC3.0/PD3.0/PPS/AFC/FCP/SCP/SSCP/VOOC/SVOOC |
| Setpoint resolution | Voltage 1 mV; current 1 mA |
| Readback resolution | Voltage 1 mV; current 1 mA |
| Setpoint accuracy (25 C) | Voltage ±(0.1%+0.025%FS); current ±(0.1%+0.08%FS) |
| Readback accuracy (25 C) | Voltage ±(0.1%+0.025%FS); current ±(0.1%+0.08%FS) |
| Ripple test | Frequency 50 Hz-500 kHz; voltage 0-3000 mV |
| Power meter adjustable AC voltage | 90, 100, 110, 120, 130, 200, 220, 240, 260 V (9 levels) |
| Overall dimensions | 480 mm D x 300.5 mm W x 110 mm H |
The AC supply must be 100-240 Vac at 47-63 Hz.
It has four load channels: CH1, CH2, CH3, and CH4.
Check the power supply, grid parameters, and fuse; contact the supplier if the fault remains.
Restart the device and ensure the network is normal; contact the supplier if it remains locked.