Asundar ASD863+651 Multi-Protocol Multi-Channel Programmable AC/DC Testing Device User Manual

ASD863+651 AC/DC testing device consists of ASD863 multi-protocol load meter, ASD651 PF digital power meter, Android operation terminal and the main function is to test the functions, parameters and performance of external power adapter PCBA and finished products. The load meter integrates 4 independent programmable multi-protocol electronic load modules. On the basis of the basic functions of ordinary electronic load meters, it also supports QC, PD fast charging protocols, and can be expanded independently to 6 load modules. It supports multiple power interfaces, and is equipped with automatic testing function, which can quickly complete the functional testing and parameter testing of power adapter.


Asundar ASD863+651 Multi-Protocol Multi-Channel Programmable AC/DC Testing Device User Manual - cover page
Brand
Asundar
Category
Test Set
Document type
User Manual
Language
Chinese
Pages
28
File format
PDF
File size
3.4 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
7F68401D20A738F691D2712C59FB5472

About this manual

The Asundar ASD863+651 AC/DC testing device consists of an ASD863 multi-protocol load tester, an ASD651 PF digital power meter, and an Android operation terminal. It is mainly used for functional detection, parameter testing, and performance evaluation of external power supplies such as power adapters, PCBA, and finished products.

The load tester integrates four independent programmable multi-protocol electronic load modules and supports manual research mode and automatic testing. It supports QC, PD, PPS, AFC, FCP, SCP, SSCP, VOOC, and SVOOC protocols, and can export test results to USB storage devices. This manual is written in Chinese.

What's inside

  • Inspection and Installation
  • Quick Start
  • Technical Specifications
  • Device Connection
  • Basic Operation
  • Common Problems
  • Warranty Agreement

Specifications

Channels4 (CH1, CH2, CH3, CH4)
Voltage measurement range0-24 V
Rated current0-10 A
Rated power100 W; 150 W in production automatic test
Supported protocolsQC2.0/PD2.0/QC3.0/PD3.0/PPS/AFC/FCP/SCP/SSCP/VOOC/SVOOC
Setpoint resolutionVoltage 1 mV; current 1 mA
Readback resolutionVoltage 1 mV; current 1 mA
Setpoint accuracy (25 C)Voltage ±(0.1%+0.025%FS); current ±(0.1%+0.08%FS)
Readback accuracy (25 C)Voltage ±(0.1%+0.025%FS); current ±(0.1%+0.08%FS)
Ripple testFrequency 50 Hz-500 kHz; voltage 0-3000 mV
Power meter adjustable AC voltage90, 100, 110, 120, 130, 200, 220, 240, 260 V (9 levels)
Overall dimensions480 mm D x 300.5 mm W x 110 mm H

Frequently asked questions

What AC input does the device require?

The AC supply must be 100-240 Vac at 47-63 Hz.

How many load channels does the tester have?

It has four load channels: CH1, CH2, CH3, and CH4.

What should I check if the tester indicator does not light after power-on?

Check the power supply, grid parameters, and fuse; contact the supplier if the fault remains.

What should I do if the touchscreen locks after power-on?

Restart the device and ensure the network is normal; contact the supplier if it remains locked.

Download PDF (3.4 MB)