Ideal Logic Series Boiler Flue & Accessories Guide

This manual is for guidance only and must be read in conjunction with the Installation and Servicing instructions supplied with the boiler.


Ideal Logic Series Boiler Flue & Accessories Guide - cover page
Brand
IDEAL
Category
Heater
Document type
Installation Guide
Language
English
Pages
14
File format
PDF
File size
4.8 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
A7008EBF62C51F983910CE701D772839

About this manual

The document covers flue terminal positioning requirements with minimum spacing distances from openings, gutters, eaves, balconies, and other structures as per BS5440-1 2008. It lists flue accessory kits such as telescopic and horizontal flue terminals, roof flue kits, powered vertical flue kits, high level flue outlet kits, balcony flue outlet kits, and soffit kits, each with Ideal part numbers.

Maximum permissible flue lengths are specified for different boiler outputs: 9 metres for 24-26 kW Combi appliances, 8 metres for 30-32 kW, and 6 metres for 35-38 kW; for System and Heat models, 9 metres for 15-24 kW and 8 metres for 30 kW. Powered vertical flue allows up to 7.5 metres concentric flue plus 17 m flue pipe. Equivalent resistance values for 90° and 45° elbows are given, and minimum horizontal flue lengths are noted.

What's inside

  • FLUE SITING
  • FLUE ACCESSORIES
  • HIGH LEVEL FLUE OUTLET KIT
  • FLUEING OPTIONS
  • HORIZONTAL CONCENTRIC 100MM DIAMETER
  • ROOF FLUE SYSTEM
  • POWERED VERTICAL FLUE SYSTEM

Specifications

Maximum horizontal concentric flue length (24-26 kW Combi)9 metres minus any flue kit options or bends
Maximum horizontal concentric flue length (30-32 kW Combi)8 metres minus any flue kit options or bends
Maximum horizontal concentric flue length (35-38 kW Combi)6 metres minus any flue kit options or bends
Maximum powered vertical flue length (24-38 kW Combi)7.5 metres concentric flue and 17 m flue pipe only
90° elbow equivalent flue length resistance1 metre
45° elbow equivalent flue length resistance0.6 metre
Minimum horizontal flue length (telescopic B pack)400 mm
Minimum horizontal flue length (horizontal flue terminal 600 mm B pack)285 mm

Frequently asked questions

What is the maximum horizontal flue length for a 24-26 kW Logic Combi C boiler?

The maximum horizontal flue length is 9 metres minus any flue kit options or bends.

What components are included in the High Level Flue Outlet kit (part no. 208178)?

The kit comprises a flue elbow, a 60 mm flue exit elbow, a 60 mm horizontal flue exit, and a 60 mm x 500 mm flue outlet extension pipe.

What is the minimum horizontal flue length when using a telescopic flue B pack?

The minimum horizontal flue length is 400 mm measured from the centre line of the turret to the outside of the wall terminal.

What is the equivalent flue length resistance for a 90° elbow kit (60/100)?

The 90° elbow kit adds an equivalent flue length resistance of 1 metre.

Download PDF (4.8 MB)