The GD10P is an infrared gas detector that can detect gas leaks and raise an alarm. The product is suitable for the oil and gas industry, as well as other industries where gas leak detection is required.
The Simtronics GD10P is an infrared point gas detector designed for effective gas risk detection in diverse industrial environments, ranging from boiler rooms to onshore petrochemical plants. It utilizes solid-state silicon infrared sources to provide fast response times and long-term stability, reducing maintenance costs.
Compared to catalytic sensors, the GD10P does not require oxygen for measurement, making it suitable for inert gas atmospheres. It is immune to contamination from silicon vapors and H2S, and it features a continuous self-test function to communicate optical fouling or errors to the control system. This manual is written in Portuguese.
| Detection Method | IV Absorption, dual wavelength, dual path |
|---|---|
| Response Time (T90) | 6 sec (Option 1.6 sec) |
| Power Supply | 24 V DC (range 18-32 V DC) |
| Power Consumption | Approx. 3.5 W |
| Operating Temperature | -40°C to +65°C |
| Protection Category | IP66/IP67 |
| Housing Material | Stainless steel SIS2343 (ASTM 316) |
| Weight | Approx. 2.9 kg |
Since methane is lighter than air, the detector should be mounted in the high part of the internal area or immediately above possible leak sites.
The instrument has a total warranty of 5 years, while the IV sources have a 15-year warranty.
No, the GD10P does not require regular re-zeroing; this function is reserved for trained workshop technicians.