Force Guide 7.0 SPEL+ Language Reference Rev.9 introduces the correct usage of Force Guide 7.0.
This document is the SPEL+ Language Reference for the Epson RC+ 7.0 Option Force Guide 7.0. It lists the commands, objects, properties, statuses and results used to program force control and force guidance sequences, and states that it is to be read together with the other related manuals before the software is used.
The reference opens with a command table and an explanation of the Force Guide 7.0 properties and statuses format, then describes the common Force Object, the FS (Force Sensor), FCS (Force Coordinate System), Robot, FC (Force Control), FT (Force Trigger), FM (Force Monitor) and MP (Mass Properties) objects, the Force Guide sequence results, object designation and constants, followed by the alphabetical entries for individual commands, properties and statuses.
| Supported operating systems | Windows 8 and Windows 10 |
|---|---|
| Force value unit | N (newton) |
| Upper threshold setting range (FT UpperLevels) | Minimum -1000, Maximum 1000 (default) |
It contains the information necessary for the correct use of the Force Guide 7.0, listing the SPEL+ commands, objects, properties, statuses and results for force control.
Windows 8 and Windows 10; in some cases the manual refers to them generically as Windows.
Use FSet with the UpperLevels property of an FT object, passing values for Fx, Fy, Fz, Tx, Ty and Tz and optionally Fmag and Tmag.
The force values such as rValueFx, rValueFy and rValueFz are given in newtons [N].