NEC TOKIN EA2/EB2 relay is a standard miniature signal relay, compact and flat. Features include compact and light weight, FCC (1500 V) surge capacity, UL recognized and CSA certified, and low power consumption (100-200 mW). Applications include electronic switching system, PBX, terminal equipment and telephone system.
This datasheet covers the NEC TOKIN EA2/EB2 series miniature signal relay, a standard relay in a compact, flat package with 2 Form C contacts. Stated features include compact and light weight construction, FCC (1500 V) surge capacity, UL recognition, CSA certification and low power consumption of 100-200 mW. Listed applications are electronic switching systems, PBX, terminal equipment and telephone systems.
The document provides dimensions and pad layouts for the EA2 and EB2 series, pin configurations and markings, general specifications, and coil specifications for non-latch, single coil latch and double coil latch types. It also includes safety standard ratings, the part number system, ordering part numbers and performance data such as coil temperature rise and switching capacity. It was issued by NEC TOKIN Corporation on August 3, 2007 (document PO886EMDDO3V0L01E).
| Contact form | 2 Form C |
|---|---|
| Contact material | Silver alloy with gold alloy overlay |
| Maximum switching power | 30 W, 62.5 VA |
| Maximum switching voltage | 220 VDC, 250 VAC |
| Maximum switching current | 1 A |
| Maximum carrying current | 2 A |
| Initial contact resistance | 75 mΩ max. (initial) |
| Operate time (excluding bounce) | Approx. 2 ms |
| Release time (excluding bounce) | Approx. 1 ms |
| Insulation resistance | 1000 MΩ at 500 VDC |
| Ambient temperature | -40 to +85 °C |
| Coil operating power | 100-200 mW |
| Weight | Approx. 1.5 g |
The datasheet lists electronic switching systems, PBX, terminal equipment and telephone systems as applications.
Yes. It is UL recognized under UL508 (File No. E73266) and CSA certified under CSA C22.2 No.14 (File No. LR46266).
Non-latch, single coil latch and double coil latch types are available, with nominal coil voltages of 3, 4.5, 5, 12 and 24 VDC.
NEC TOKIN recommends driving the non-latch type with a voltage within 5% of the nominal voltage, using a square pulse with rapid rise and fall.