This document is an installation manual for FAGOR Advance Plus series ovens.
This Spanish-language installation manual covers the FAGOR ADVANCE + / ADVANCE PLUS oven models APE-061, APE-101, APE-201, APE-102 and APE-202. It starts with general safety instructions and warnings, then describes installation of countertop models, minimum distances, electrical connection, water connection, overall dimensions and depalletizing.
The manual specifies a minimum distance of 400 mm on the left side near heat sources and recommends 500 mm on the left side for repair and maintenance work. Electrical connection must be made by an authorized technician; cable sections and fuse values are listed for 400 V 3N and 230 V 3N supplies, and a disconnect switch with at least 3 mm contact opening is required. The final pages are in Italian and include error-code descriptions and environmental disposal notes. This manual is written in Spanish.
| Minimum distance from heat sources on left side | 400 mm |
|---|---|
| Recommended left-side clearance for repair and maintenance | 500 mm |
| Disconnect switch contact opening | At least 3 mm |
The manual covers ADVANCE + models APE-061, APE-101, APE-201, APE-102 and APE-202.
A minimum distance of 400 mm is required on the left side.
The electrical connection must always be made by an authorized technician.
The manual recommends cleaning the interior with a cloth moistened with soapy water.