The Tuthill TT10P is an in-line turbine flow meter with the following features:
The TT10P is an electronic in-line turbine meter for hazardous locations and extreme temperatures. It stores and displays batch or totalizer volumes in ounces, pints, quarts, liters, or gallons, and offers 20 preset calibration factors for different fluid viscosities.
Installation, unit changes, fluid calibration, flush mode, accumulated-total reset, K-factor check, and battery replacement are described. Safety limits include a maximum internal pressure of 125 PSI (8.6 Bar) for TT10P models and proper grounding near flammable fluids.
| Flow Ports | 1" NPT or BSPP female inlet and outlet ports |
|---|---|
| Flow Range | 2 to 35 U.S. GPM / 7.6 to 132.5 LPM |
| Maximum Internal Pressure (TT10P) | 125 PSI (8.6 Bar) |
| Working Pressure at or below 120°F (49°C) | 125 PSI (8.6 Bar) |
| Working Pressure above 120°F (49°C) | 50 PSI (3.5 Bar) |
| Storage Temperature | -40°F to 176°F (-40°C to 60°C) (no liquids) |
| Operating Temperature | -15°F to 176°F (-26°C to 60°C) |
| Measurement Repeatability | ±0.30% (batch sizes ≥ 2 gallons) |
| Measurement Units | Ounce, pint, quart, liter, gallon |
| Totalizer Range | 0 - 90,000,000 units |
| Batch Range | 0.00 - 9999 units (blinks when batch exceeds 9999) |
| Wetted Materials | 304/316 stainless steel, polypropylene, UHMWPE, gold |
| Display Temperature Range | -40°F to 176°F (-40°C to 60°C) |
| Power | 2 approved alkaline batteries |
| Memory | Meter totals and calibration preserved when replacing batteries |
| Safety | Intrinsically safe electronics for use in hazardous locations |
| Fluid Viscosity Compatibility | 0.4 cSt to 79 cSt |
2 to 35 U.S. GPM (7.6 to 132.5 LPM).
Ounces, pints, quarts, liters, and gallons.
Hold buttons ON and 4 together for 5 seconds to reset the accumulated total.