Tuthill TT10P In-line Turbine Flow Meter Operation and Safety Manual

The Tuthill TT10P is an in-line turbine flow meter with the following features:


Tuthill TT10P In-line Turbine Flow Meter Operation and Safety Manual - cover page
Brand
Tuthill
Category
Other products
Document type
User Manual
Language
English
Pages
36
File format
PDF
File size
724 KB
Published
10 November, 2023
Updated
10 November, 2023
Model
TT10P
MD5 checksum
A628357C6BE295B8B62AA0FF72AE8938

About this manual

The TT10P is an electronic in-line turbine meter for hazardous locations and extreme temperatures. It stores and displays batch or totalizer volumes in ounces, pints, quarts, liters, or gallons, and offers 20 preset calibration factors for different fluid viscosities.

Installation, unit changes, fluid calibration, flush mode, accumulated-total reset, K-factor check, and battery replacement are described. Safety limits include a maximum internal pressure of 125 PSI (8.6 Bar) for TT10P models and proper grounding near flammable fluids.

What's inside

  • General Description
  • Fluid and Viscosity Compatibility
  • Installation
  • Electronic Module Orientation
  • Operational Functions
  • Changing Units of Measure
  • Fluid Calibration
  • Flush Mode (FLSH)
  • Reset Accumulated Total
  • Battery Replacement

Specifications

Flow Ports1" NPT or BSPP female inlet and outlet ports
Flow Range2 to 35 U.S. GPM / 7.6 to 132.5 LPM
Maximum Internal Pressure (TT10P)125 PSI (8.6 Bar)
Working Pressure at or below 120°F (49°C)125 PSI (8.6 Bar)
Working Pressure above 120°F (49°C)50 PSI (3.5 Bar)
Storage Temperature-40°F to 176°F (-40°C to 60°C) (no liquids)
Operating Temperature-15°F to 176°F (-26°C to 60°C)
Measurement Repeatability±0.30% (batch sizes ≥ 2 gallons)
Measurement UnitsOunce, pint, quart, liter, gallon
Totalizer Range0 - 90,000,000 units
Batch Range0.00 - 9999 units (blinks when batch exceeds 9999)
Wetted Materials304/316 stainless steel, polypropylene, UHMWPE, gold
Display Temperature Range-40°F to 176°F (-40°C to 60°C)
Power2 approved alkaline batteries
MemoryMeter totals and calibration preserved when replacing batteries
SafetyIntrinsically safe electronics for use in hazardous locations
Fluid Viscosity Compatibility0.4 cSt to 79 cSt

Frequently asked questions

What is the flow range of the TT10P meter?

2 to 35 U.S. GPM (7.6 to 132.5 LPM).

What units can the TT10P display?

Ounces, pints, quarts, liters, and gallons.

How do I reset the accumulated total?

Hold buttons ON and 4 together for 5 seconds to reset the accumulated total.