Installation and service instructions for the Tuthill 1LEV-C-7 positive displacement gear pump, covering setup, operation, maintenance, and troubleshooting.
This document provides installation and service instructions for the Tuthill 1LEV-C-7 positive displacement gear pump. It details the general description of the LA and LE series pumps, their pumping principle, and specific requirements for location and proper installation to ensure safe and efficient operation. The guide emphasizes safety precautions, such as disconnecting the drive before work and checking fluid compatibility with residual factory oil.
| Series | LA and LE Series |
|---|---|
| Capacity Range | .5 gpm (1.9 L/Min) to 14 gpm (53 L/Min) |
| Maximum Pressure | 500 psi (300 psi in the 5LE) |
| Viscosity Range | 35 to 1000 SSU |
| Residual Oil | 200 SSU lube oil |
| Relief Valve Range | 55-120 psi (40-70 in the 5LE) |
The document warns that the pump contains residual 200 SSU lube oil and users must determine if this is compatible with the fluid being pumped.
Pumps with ports on the same plane should be installed with both ports pointing upward to ensure proper priming.
Direct drive through a traditional flexible coupling is recommended, though the coupling should not be relied upon to compensate for misalignment.
No, the internal relief valve is designed for overpressure protection only and is not intended as a flow control device.