Inovance MD200 AC Drive General Purpose Open Loop A05 Data Code 19010379 User Guide

MD200 AC Drive General Purpose, Open Loop A05 Data code 19010379 User Guide


Inovance MD200 AC Drive General Purpose Open Loop A05 Data Code 19010379 User Guide - cover page
Brand
Inovance
Category
inverter
Document type
User Manual
Language
English
Pages
61
File format
PDF
File size
2 MB
Published
09 November, 2023
Updated
09 November, 2023
MD5 checksum
EDC62F3E076D4F69F7B12A5DAA490125

About this manual

This guide is packaged with the MD200 AC Drive and contains basic information for quick start. It covers safety precautions, product information, mechanical installation and wiring, the operating panel, quick setup, the parameter table, and troubleshooting.

The MD200 series includes 200-240 V and 380-480 V models with motor ratings from 0.4 kW to 3.7 kW. Specifications include input and output ratings, dimensions, overload capacity, carrier frequency, maximum output voltage and frequency, braking resistor recommendations, and weight.

What's inside

  • Safety Information and Precautions
  • Product Information
  • Mechanical Installation and Wiring
  • Operating Panel
  • Quick Setup
  • Parameter Table
  • Troubleshooting

Specifications

Voltage class200-240 VAC or 380-480 VAC
Model seriesMD200SxxB (200 V) and MD200TxxB (380 V)
Dimensions160 mm high, 75 mm wide, 145 mm deep
Mounting holeΦ5.0 mm
Rated input voltage (200 V models)1 PH, 200-240 VAC, -15% to +10%
Rated input voltage (380 V models)3 PH, 380-480 VAC, -15% to +10%
Rated input frequency50/60 Hz, ±5%
Output current2.6-11.0 A (200 V models); 1.8-9.5 A (380 V models)
Applicable motor power0.4-2.2 kW (200 V models); 0.4-3.7 kW (380 V models)
Default carrier frequency6 kHz (most models); 4 kHz (380 V, 3.7 kW)
Overload capacity150% for 60 s
Maximum output voltage0-240 VAC (200 V models); 0-480 VAC (380 V models)
Maximum output frequency50 to 500 Hz
Braking resistorRecommended power 80-400 W; minimum resistance 70-300 Ω by model
Weight1.1 kg

Frequently asked questions

What is this guide for?

It is packaged with the MD200 AC Drive and provides basic information for quick start.

Where can I get the full user manual?

The full MD200 AC Drive User Manual can be downloaded from the Inovance website.

What certifications may the MD200 comply with?

The listed certifications include CE and TUV.

How long should I wait after disconnecting power before servicing?

Wait at least 10 minutes after isolating the AC supply before working on the drive.

Download PDF (2 MB)