This guide details the naming rules, debugging steps, terminal wiring, parameter settings, and pole detection for using the Inovance SV-DA300 servo drive…
This technical guide is designed for the Inovance SV-DA300 series AC servo drive, specifically addressing the differences and requirements when driving linear motors compared to rotary motors. It covers the specific naming conventions for linear motor dedicated drives, including power ratings, voltage levels, and communication types.
The document provides step-by-step instructions for debugging, including terminal wiring for the second encoder interface (CN5), parameter configuration for motor pitch and resolution, and procedures for selecting motor phase sequence. It also explains the necessary magnetic pole detection process to ensure the electrical angle coordinate is correctly acquired before normal motion control can begin. This manual is written in Chinese.
| Max Encoder Input Speed | 3M lines/sec |
|---|---|
| Encoder Interface Port | CN5 |
| Power Supply Voltage Options | 220VAC, 400VAC |
| Power Ratings | 100W, 200W, 400W, 750W, 1.0kW |
Move the motor manually to confirm the feedback pulse count matches the distance moved, then adjust parameters P9.20, P9.21, and P9.26 while incrementing P9.22 to match the encoder counting direction.
You can start detection via parameter P6.50, by configuring an IO port as PDET (0x34), or by configuring an IO port as SON (0x03).
System status code 2 indicates that the magnetic poles have not been determined yet (磁极未确定).