SICK STR1-SASU03P5 STR1 Non-Contact Safety Switch Datasheet

The STR1-SASU03P5 is a non-contact safety switch with 2 safety outputs and 1 auxiliary contact (AUX).


SICK STR1-SASU03P5 STR1 Non-Contact Safety Switch Datasheet - cover page
Brand
SICK
Category
switch
Document type
Datasheet
Language
Chinese
Pages
7
File format
PDF
File size
523 KB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
B0B4974860AE7945348416F95D189776

About this manual

This is the SICK online data sheet (dated 2018-07-31) for the STR1-SASU03P5 non-contact safety switch, part of the STR1 series. It lists the sensor's technical and safety-related data, mechanical and environmental parameters, dimensional drawings, approach ranges for the actuator and the wiring diagram.

The document states safety integrity level SIL3 (IEC 61508) / SILCL3 (EN 62061), Category 4 and PL e (EN ISO 13849), Type 4 with high coding (EN ISO 14119), a 24 V DC supply, a 40 mm x 18 mm x 26 mm housing rated IP67 and IPX9K, and a 5-pin cable connection. It ends with accessory information and a short SICK company profile. This manual is written in Chinese.

What's inside

  • Technical data
  • Safety technical data
  • Electrical data
  • Mechanical data
  • Environmental data
  • Dimensional drawing
  • Approach ranges and safe switching distance
  • Wiring diagram
  • Accessories
  • Classification (ECLASS, ETIM)

Specifications

Safety integrity levelSIL3 (IEC 61508), SILCL3 (EN 62061)
Performance level / categoryPL e, Category 4 (EN ISO 13849)
Mission time (TM)20 years (EN ISO 13849)
Type according to EN ISO 14119Type 4, high coding level
Supply voltage24 V DC (19.2 V DC … 28.8 V DC)
Current consumption50 mA
Dimensions (W x H x D)40 mm x 18 mm x 26 mm
Weight170 g
Enclosure ratingIP67 (EN 60529), IPX9K (ISO 20653)
Operating temperature-10 °C … +70 °C
Housing materialVISTAL

Frequently asked questions

What safety integrity level and performance level does the STR1-SASU03P5 achieve?

The datasheet states SIL3 (IEC 61508) and SILCL3 (EN 62061), Category 4 and PL e according to EN ISO 13849, with a mission time of 20 years.

What supply voltage does the safety switch need?

It is supplied with 24 V DC, with a permitted range of 19.2 V DC to 28.8 V DC, and consumes 50 mA.

How is the STR1-SASU03P5 wired?

Brown is the 24 V DC supply, White is OSSD1, Blue is 0 V DC, Black is OSSD 2 and Grey is the auxiliary output, which is not safe.

What is the enclosure rating and operating temperature?

The housing is rated IP67 (EN 60529) and IPX9K (ISO 20653) and is approved for an operating temperature of -10 °C to +70 °C.