MS-12TE / MS-12FE Dual Zone Outdoor PIR Motion Detector Instruction Manual

The MS-12TE / MS-12FE Dual Zone Outdoor PIR Motion Detector is an outdoor detector that features dual zone detection, allowing it to detect two areas simultaneously. It is also weatherproof, allowing it to be used in harsh weather conditions.


MS-12TE / MS-12FE Dual Zone Outdoor PIR Motion Detector Instruction Manual - cover page
Category
sensor
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
570 KB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
D54F9CE91E9EA2FE49C4DCBD39D35333

About this manual

This instruction manual describes the MS-12TE and MS-12FE dual zone outdoor PIR motion detectors. It covers parts description, precautions, detection area patterns and coverage, horizontal and wall detection, detection distance adjustment, area masking, and mode settings. It explains installation precautions such as maintaining an install height of 2.6' to 4.0' (0.8 to 1.2 m), avoiding exhaust vents, strong light, and electrical noise.

The adjustment sections cover sensitivity adjustment from 30% to 170%, delay time from about 2 sec to 5 min, selectable N.O./N.C. contact output, LED ON/OFF, and pulse count. The MS-12FE has two sets of switches for the upper and lower sensor and a selectable AND or OR detection mode.

What's inside

  • Parts Description
  • Precautions
  • Detection Area
  • Patterns of Coverage
  • Detection Distance Adjustment
  • Area Masking Sheet
  • Adjustment
  • Important Notes

Specifications

ModelsMS-12TE and MS-12FE
Installation height2.6' to 4.0' (0.8 to 1.2 m)
Detection distance adjustment range6.6' (2 m) to 40' (12 m), 10 ranges
Horizontal adjustment90°
Variable range180°
Delay timeApprox. 2 sec to 5 min; factory set 2 sec
Sensitivity adjustment30% (L) to 170% (H); factory set 100%
Contact outputN.O. or N.C. selectable
Detection modeAND or OR, only applicable to MS-12FE
Area masking sheetMS-12FE: 2 pcs; MS-12TE: 1 pc

Frequently asked questions

What installation height is recommended?

Keep the install height from 2.6' to 4.0' (0.8 to 1.2 m).

How long is the sensor stabilizing period after power is supplied?

The Operation LED blinks for about 1 minute after power is supplied, and the unit does not operate during this sensor stabilizing period.

What detection distance can be set?

The detection distance is set by adjusting the angle of the downward zone, with an adjustable range of 6.6' (2 m) to 40' (12 m) in 10 ranges.

What does the AND detection mode do on the MS-12FE?

An alarm signal is issued only when both the upper and lower sensors detect objects simultaneously.

Download PDF (570 KB)