The Lvqing QZX327 sensor detects tiny human motions using ultra‑wideband radar and provides RS485 output for smart devices.
About this manual
The QZX327 human micro‑motion sensor uses ultra‑wideband radar and biomedical engineering to detect body presence, breathing and subtle movements. It is suited for smart toilets, robots, offices, conference rooms, restrooms and hospitals.
The manual details electrical parameters, communication settings, device functions, installation, wiring, remote‑control adjustments and safety precautions for reliable operation. This manual is written in Chinese.
What's inside
- Product Overview
- Electrical Parameters
- Communication Parameters
- Device Functions
- Installation and Wiring
- Remote‑Control Settings
- Usage Precautions
Specifications
| Input Voltage | DC 8‑12 V |
|---|
| Working Current | < 90 mA |
|---|
| Detection Angle (FOV) | 85° × 85° |
|---|
| Output Mode | RS485 and passive switch signal |
|---|
| Product Size | 75 mm × 25 mm |
|---|
| Detection Distance (Dynamic) | < 5 m |
|---|
| Detection Distance (Static) | < 2 m |
|---|
| Operating Temperature | -40 °C to 85 °C |
|---|
| Wiring Cable | 4 × 0.5 mm²‑L180 mm |
|---|
| Installation Method | Ceiling mount |
|---|
| Communication Interface | RS485 |
|---|
| Supported Protocols | ASCII / MODBUS RTU |
|---|
| Baud Rate Options | 9600, 8, n, 1 |
|---|
| Electrical Isolation | 1000 VDC |
|---|
| Wave Rate Options | 2400‑38400 bps |
Frequently asked questions
How do I adjust the sensor's sensitivity?
Press the sensitivity key, then press a number 1‑9; level 1 is least sensitive, level 9 is most sensitive (default 9).
How can I reset the sensor to factory defaults?
Press and hold the “C” key for five consecutive presses to restore factory settings.
What are the detection distances for dynamic and static targets?
The sensor detects dynamic body movement up to 5 m and static breathing motion up to 2 m.
Which communication protocols does the QZX327 support?
It supports RS485 with ASCII and MODBUS RTU protocols.