This product is a bathroom thermo ventilator, model V-251BZ-HK, voltage 220 V single-phase.
This installation manual is for the Mitsubishi Electric V-251BZ-HK bathroom thermo ventilator and is intended for dealers and contractors. It covers safety precautions, part names and dimensions, installation position selection, installation method, post-installation checks, trial operation, initial value settings, customer explanations and troubleshooting.
The manual states that the product is for bathroom ceiling installation only and requires a 220 V AC single-phase power supply. It also lists installation dimensions, supplied parts, safety warnings and checks to be completed after installation. This manual is written in Chinese.
| Power supply | 220 V AC single-phase |
|---|---|
| Standard supported bathroom floor area | 2.9 m2 |
| Minimum installation height above floor | 2.3 m |
| Earth leakage circuit breaker leakage current | not exceeding 30 mA |
| Circuit breaker rating | 16 A or greater |
| Contact separation | at least 3 mm |
| Ceiling crawl space | at least 190 mm |
| Inspection hole size | at least 45 cm square |
| Baffle plate movement range | 60° to 120° |
The unit must use a 220 V AC single-phase power supply.
The product is for bathroom ceiling installation only.
The product must be installed at least 2.3 m above the floor.
The standard supported size is a bathroom with a floor area of 2.9 m2.