This product is a bathroom thermo ventilator, model V-251BZ-HK, voltage 220 V single-phase.


Mitsubishi Electric V-251BZ-HK Bathroom Thermo Ventilator Installation Manual - cover page
Brand
Mitsubishi Electric
Category
Other products
Document type
Installation Guide
Language
Chinese
Pages
16
File format
PDF
File size
4.3 MB
Published
06 November, 2023
Updated
06 November, 2023
MD5 checksum
D57DF417A3394509292CB4A82EC3FECF

About this manual

This installation manual is for the Mitsubishi Electric V-251BZ-HK bathroom thermo ventilator and is intended for dealers and contractors. It covers safety precautions, part names and dimensions, installation position selection, installation method, post-installation checks, trial operation, initial value settings, customer explanations and troubleshooting.

The manual states that the product is for bathroom ceiling installation only and requires a 220 V AC single-phase power supply. It also lists installation dimensions, supplied parts, safety warnings and checks to be completed after installation. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • Names and Dimensions of Parts
  • Selecting Installation Position
  • Method of Installation
  • Checks after Installation
  • Trial Operation
  • Checking and Changing Initial Values
  • Explanations to the Customer
  • Troubleshooting

Specifications

Power supply220 V AC single-phase
Standard supported bathroom floor area2.9 m2
Minimum installation height above floor2.3 m
Earth leakage circuit breaker leakage currentnot exceeding 30 mA
Circuit breaker rating16 A or greater
Contact separationat least 3 mm
Ceiling crawl spaceat least 190 mm
Inspection hole sizeat least 45 cm square
Baffle plate movement range60° to 120°

Frequently asked questions

What power supply is required for the V-251BZ-HK?

The unit must use a 220 V AC single-phase power supply.

Where can the V-251BZ-HK be installed?

The product is for bathroom ceiling installation only.

How high above the floor must the unit be installed?

The product must be installed at least 2.3 m above the floor.

What bathroom size is the standard supported size?

The standard supported size is a bathroom with a floor area of 2.9 m2.